The BMC is a small controller inside a server, IPMI its interface for power, sensors and logs. Why it must never face the open internet.

This entry is still below our minimum bar for the search index (length and number of sources) and is being reworked. It is therefore not listed in search engines.

Your server has a second, tiny computer that never sleeps and can press the power button for you. Treat it with the respect that deserves.

The short answer

A BMC (baseboard management controller) is a small, separate controller on a server board that manages the machine at hardware level, even when the operating system is down. IPMI (Intelligent Platform Management Interface) is the long-standing interface specification that the BMC speaks [1][3]. Should you expose it to the internet? No. CISA advises restricting IPMI access to specific management addresses, preferably in a separate network segment [1]. Our assessment: use it for power control, sensors and logs, but keep it off the open internet.

How it works

  1. What the BMC does. CISA describes IPMI as a low-level interface that lets an administrator manage servers at hardware level; it runs on the BMC and gives access to the BIOS, disks and other hardware, including remote boot and monitoring of the server environment [1]. Out-of-band means it works even if the server's operating system is not running.
  2. Where IPMI comes from. The IPMI specification, version 2.0, is published by Intel [3]. Many hardware makers adopted it [1]. HPE calls its implementation iLO (Integrated Lights-Out), Dell calls it iDRAC, and other makers use other names (our summary, unverified for each maker here).
  3. The tool. ipmitool manages IPMI functions of the local system or a remote one, including FRU information, LAN configuration, sensor readings and remote chassis power control [2]. Remote management requires that the IPMI-over-LAN interface is enabled and configured [2].
  4. Interface choice. For remote sessions, the manual describes lan and lanplus; the lanplus interface uses IPMI v2.0 and, by default, cipher suite 17 (RAKP-HMAC-SHA256, AES-CBC-128). Versions up to 1.8.18 defaulted to suite 3, which the manual calls insecure [2]. Our assessment: use lanplus and a current version.
  5. The risk. CISA lists weaknesses reported by researcher Dan Farmer: passwords saved in clear text, one password working for a whole IPMI group, little monitoring for a compromised BMC, and some unencrypted traffic [1]. An attacker with BMC access can reboot the machine or install a new operating system, bypassing the operating system's own controls [1]. That text dates from 2013 (revised 2016), so read your vendor's current advisories [1].
  6. Redfish as the newer way. The DMTF's Redfish specification defines a REST-based management interface, and many vendors offer it next to IPMI [4]. Our assessment: where your BMC supports Redfish, prefer it and switch IPMI-over-LAN off if you do not need it.
  7. Your vendor's console. HPE documents the settings of its iLO in the iLO user guide [5]. Whether IPMI over LAN is switched on by default for your generation is unverified here, so read it in your own iLO.

A homelab example

The Bytearium homelab runs rack servers (HPE ProLiant DL360 Gen9 and DL380 Gen10) and a QNAP NAS, as of 14 to 18 Oct 2026. We have not recorded their iLO or IPMI settings, so we say nothing about them. A general walkthrough for your own server: put the management port into a separate network or VLAN, give it a reserved address, and check in the controller's access settings whether IPMI over LAN is on. If you use it, query it from a trusted machine with ipmitool -I lanplus -H <address> -U <user> -a chassis power status and enter the password at the prompt [2]. Avoid typing the password into the command line, where other users of the machine could see it (our assessment).

Checklist

  • Find the management port of your server and connect it to a separate network.
  • Check that the management address is not forwarded or reachable from the internet [1].
  • Change default accounts and use a long, unique password.
  • Check whether IPMI over LAN is enabled and switch it off if you do not need it [2][5].
  • Use lanplus and an ipmitool version newer than 1.8.18 [2].
  • Update the BMC firmware after reading the vendor's advisories.
  • Test power status and the event log from a trusted machine.
  • Prefer Redfish where your BMC offers it [4].

Primary sources

These sources are the basis of this page. That does not mean every claim was checked individually; whether a review record exists is shown above under “Status”. The interpretation and checklist are our own work.

There is no documented review record for this version yet. The text relies on the sources listed.

How this page was made: Bytearium creates these pages with the help of AI and is responsible for publishing them. AI can be wrong, so we show our sources and review status openly.

  1. CISARisks of Using the Intelligent Platform Management Interface (IPMI)
  2. Debian Manpagesipmitool(1)
  3. IntelIPMI Second Generation Interface Specification v2.0, Rev. 1.1
  4. DMTFDSP0266, Redfish Specification
  5. Hewlett Packard EnterpriseHPE iLO user guide

This page has no ads and no affiliate links.